Main Article Content
Abstract
Metal-based partial dentures (MPDs) are a common treatment option for the rehabilitation of partially edentulous patients. However, conventional protocols can be complex and prone to error. The integration of digital technologies helps to improve accuracy and patient comfort. This paper presents a clinical case study of a digitally-assisted PAPM fabricated for a patient with facial paralysis. A 55-year-old female patient, presenting with paralysis of the left side of her body following meningoencephalitis, consulted for prosthetic rehabilitation. The clinical examination revealed facial asymmetry, limited mouth opening, partial edentulism of the maxilla and mandible, and a reduction in the vertical dimension of occlusion. These factors made prosthetic management complex. A PAPM replacing 13 teeth in the maxilla and 5 teeth in the mandible was fabricated using a protocol incorporating a partial digital workflow. This included an optical impression of the dental arches, a digital record of the intermaxillary relationship and virtual design of the prosthetic frameworks prior to their fabrication. The clinical outcome demonstrated good prosthetic fit, as well as an improvement in the patient’s mastication, speech and comfort. This clinical case highlights the benefits of the digital workflow in the fabrication of metal-based removable partial dentures for patients with complex clinical presentations. Optical impression-taking and digital design help to simplify certain stages of treatment, reduce patient discomfort and improve the accuracy of treatment. Despite the limitations on access to digital technologies in certain contexts, this approach offers a promising avenue for optimising prosthetic rehabilitation.
Keywords
Article Details

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
References
- 1. Ahmed S, Hawsah A, Rustom R, Alamri A, Althomairy S, Alenezi M, Shaker S, Alrawsaa F, Althumairy A, Alteraigi A. Digital Impressions Versus Conventional Impressions in Prosthodontics: A Systematic Review. Cureus. 2024 2;16(1):e51537.
- 2. Dawid MT, Moldovan O, Rudolph H, Kuhn K, Luthardt RG. Technical Complications of Removable Partial Dentures in the Moderately Reduced Dentition: A Systematic Review. Dent J (Basel). 2023 20;11(2):55
- 3. Fueki K, Inamochi Y, Wada J, Arai Y, Takaichi A, Murakami N, Ueno T, Wakabayashi N.A systematic review of digital removable partial dentures.Part I: Clinical evidence, digital impression, and maxillomandibular relationship record. J Prosthodont Res. 2022 11;66(1):40-52
- 4. Kouamé KM, Allou AG, Kouadio AA, Kouadio KR, N’guessan KS, Amani SR, N’goran KJ, Djérédou KB. Adoption du Scanner Intra-Oral par les Chirurgiens-Dentistes en Côte d'Ivoire : État des Lieux et Facteurs Influençant son utilisation. Health Sci. Dis 2024 25 (4) : 53-57.
- 5. Lo Russo L, Zhurakivska K, Guida L, Chochlidakis K, Troiano G, Ercoli C. Comparative cost-analysis for removable complete dentures fabricated with conventional, partial, and complete digital workflows. J Prosthet Dent. 2024131(4):689-96.
- 6. Mangano F, Gandolfi A, Luongo G, Logozzo S. Intraoral scanners in dentistry: a review of the current literature. BMC Oral Health. 2017 12;17(1):149.
- 7. Mendes,TA, Marques D., Lopes LP et Caramês, J. 2019. Flux de travail entièrement numérique pour la fabrication d'une prothèse dentaire partielle amovible : étude de cas. SAGE Open Med. Case Rep. 7 : 2050313x19871131. doi: 10.1177/2050313x19871131.
- 8. Nishiyama H, Taniguchi A, Tanaka S, Baba K. Novel fully digital workflow for removable partial denture fabrication. J Prosthodont Res. 2020;64(1):98-103.
- 9. Piao, X.-Y.; Jeon, J.; Shim, J.-S.; Park, J.-M. A Digital Workflow for the Fabrication of a Milled Removable Partial Denture. Int. J. Environ. Res. Public Health 2022, 19, 8540.
- 10. Rudd RW, Rudd KD. A review of 243 errors possible during the fabrication of a removable partial denture: part I. J Prosthet Dent. 2001 ;86 (3) :251-61
References
1. Ahmed S, Hawsah A, Rustom R, Alamri A, Althomairy S, Alenezi M, Shaker S, Alrawsaa F, Althumairy A, Alteraigi A. Digital Impressions Versus Conventional Impressions in Prosthodontics: A Systematic Review. Cureus. 2024 2;16(1):e51537.
2. Dawid MT, Moldovan O, Rudolph H, Kuhn K, Luthardt RG. Technical Complications of Removable Partial Dentures in the Moderately Reduced Dentition: A Systematic Review. Dent J (Basel). 2023 20;11(2):55
3. Fueki K, Inamochi Y, Wada J, Arai Y, Takaichi A, Murakami N, Ueno T, Wakabayashi N.A systematic review of digital removable partial dentures.Part I: Clinical evidence, digital impression, and maxillomandibular relationship record. J Prosthodont Res. 2022 11;66(1):40-52
4. Kouamé KM, Allou AG, Kouadio AA, Kouadio KR, N’guessan KS, Amani SR, N’goran KJ, Djérédou KB. Adoption du Scanner Intra-Oral par les Chirurgiens-Dentistes en Côte d'Ivoire : État des Lieux et Facteurs Influençant son utilisation. Health Sci. Dis 2024 25 (4) : 53-57.
5. Lo Russo L, Zhurakivska K, Guida L, Chochlidakis K, Troiano G, Ercoli C. Comparative cost-analysis for removable complete dentures fabricated with conventional, partial, and complete digital workflows. J Prosthet Dent. 2024131(4):689-96.
6. Mangano F, Gandolfi A, Luongo G, Logozzo S. Intraoral scanners in dentistry: a review of the current literature. BMC Oral Health. 2017 12;17(1):149.
7. Mendes,TA, Marques D., Lopes LP et Caramês, J. 2019. Flux de travail entièrement numérique pour la fabrication d'une prothèse dentaire partielle amovible : étude de cas. SAGE Open Med. Case Rep. 7 : 2050313x19871131. doi: 10.1177/2050313x19871131.
8. Nishiyama H, Taniguchi A, Tanaka S, Baba K. Novel fully digital workflow for removable partial denture fabrication. J Prosthodont Res. 2020;64(1):98-103.
9. Piao, X.-Y.; Jeon, J.; Shim, J.-S.; Park, J.-M. A Digital Workflow for the Fabrication of a Milled Removable Partial Denture. Int. J. Environ. Res. Public Health 2022, 19, 8540.
10. Rudd RW, Rudd KD. A review of 243 errors possible during the fabrication of a removable partial denture: part I. J Prosthet Dent. 2001 ;86 (3) :251-61
